Benchmark metrics

{{CLIENT_NAME}}

{{TIMEZONE}} · {{UTC_OFFSET}}

This page displays reference vibration standards and the configured benchmark record for the selected equipment. Demo baseline records are shown as controlled gold-mine comparison data.
ISO 20816-1 vibration standards reference
Group Description Zone A (good) Zone B (acceptable) Zone C (alert) Zone D (danger)
Group 1 Large machines, rigid foundation 0 to 2.3 2.3 to 4.5 4.5 to 7.1 > 7.1
Group 2 Large machines, flexible foundation 0 to 3.5 3.5 to 7.1 7.1 to 11.0 > 11.0
Group 3 Medium machines 0 to 1.4 1.4 to 2.8 2.8 to 4.5 > 4.5
Group 4 Small machines 0 to 0.7 0.7 to 1.8 1.8 to 4.5 > 4.5
Per ISO 20816-1 Table A.1, vibration zone thresholds vary by machine group. Group 1 applies to large machines on rigid foundations. Group 2 applies to large machines on flexible foundations with higher allowable vibration. Group 3 and 4 apply to smaller and medium machines with correspondingly stricter thresholds.
Additional ISO standards
Standard Description Zone A (good) Zone B (acceptable) Zone C (alert) Zone D (danger)
ISO 10816-3 Industrial machines (15 to 75 kW, 120 to 15000 rpm) 0 to 2.3 2.3 to 4.5 4.5 to 7.1 > 7.1
ISO 7919 Shaft vibration standards for rotating equipment 0 to 1.6 1.6 to 3.2 3.2 to 5.0 > 5.0
ISO 13373-1 Predictive maintenance and diagnostics (vibration) 0 to 2.0 2.0 to 4.5 4.5 to 7.0 > 7.0
Line 1 Main Motor – baseline comparison
Demo benchmark assets
Vertical (mm/s)Demo data loaded
Horizontal (mm/s)Demo data loaded
Axial (mm/s)Demo data loaded
Highest readingDemo data loaded
StandardDemo data loaded
Demo benchmark
Fleet benchmark summary
0
Configured positions in Zone A (good)
0
Configured positions in Zone B (acceptable)
0
Configured positions in Zone C (alert)
0
Configured positions in Zone D (danger)
Monitoring notes
Zone classification guidance:
  • Zone A: Good condition. No action required.
  • Zone B: Acceptable. Monitor trending. Plan maintenance within 1 to 2 months.
  • Zone C: Alert threshold. Increase monitoring frequency. Schedule maintenance within 2 to 4 weeks.
  • Zone D: Danger threshold. Immediate attention required. Take corrective action or reduce operating speed and load.

Benchmark readings are shown only when configured benchmark records exist. Trend Analysis and historical comparisons remain available in the diagnostic graphs section once persisted diagnostic data is present.